Price: $8,885 |
| Output Ratings: |
| Standby |
Prime |
60 HZ, 60 KW, 75.0 KVA
50 HZ, 52 KW, 62.5 KVA |
56 KW, 70 KVA
48 KW, 60 KVA |
|

|
|
|
- Engine:
Perkins 4 Cycle 4 Cylinder Turbochared in line
|
- Main Alternator:
Brushless, self regulating, screen protected and drip proof. 12 lead reconnectable
to:
208/120, 220/127, 230/115, 380/220, 415/240, 480/277
Full load current at 220 Volts, 60 HZ, .8 PF 197 Amps.
Full load current at 220 Volts, 50 HZ, .8 PF 164 Amps
|
- Governor:
Mechanical (standard), Electronic (optional)
|
- Cooling System:
Rail mounted radiator.
|
- Electrical System:
Safety shutdown in event of low oil pressure or high engine temperature.
12 Volt Battery Charging Alternator.
|
- Fuel Consumption:
Full load 60 Hz, 1800 RPM 4.91 GPH [18.90 L/HR]
Full load 50 Hz, 1500 RPM 3.73 GPH [14.36 L/HR]
|
- Instrument Panel:
| Set mounted key start panel in a vibration isolated
sheet metal enclosure with a hinged door. The control panel is equiped as follows:
|
- AC Voltmeter
- AC Ammeter
- Frequency Meter
- Volt/Amp Phase Selector Switch
- Running Time Meter
|
- Coolant Temperature Gauge
- Oil Pressure Gauge
- Battery Condition Meter
- Start/Stop Key Switch
- Oil Pressure Bypass Switch for Startup
|
|
- Documentation & Warranty:
Wiring diagram, engine manual, main alternator manual.
One Year Warranty. Copy of policy available upon request.
|